D* V*nl Tarmlncrtlon T«* Installfillon

Use only a termination tee with debris screen for vent

termination. See below for allowable termination
tees.

Hart/Coolsy

Plezco

Plexco

Item Description

Snnpe

~3““Pip0

ÏTTpe“

Termination Tee

3UT

Debris Screen
Termination Tee with

3UDS

Debris Screen

901971

906882

Caiitlom

Do not locate the vent termination closer

than 4 feet to plants or shrubbery as
combustion products may stunt or kill
them. Also see section B for proper vent
termination tee clearances.

Cautions

In some Instances, excessive conden>

sate at the termination tee can cause
staining or damage to the outside wall.
Sealing or shielding of outside wall with
a corrosion resistant material (such as
aluminum sheet) may be necessary.

1. Installing Termination Tee

a.

Use approved sealant to join termination tee

to section of vent pipe protruding from
thimble. Termination tee must be in vertical
position. See Figure 5.

b.

Make sure debris screens are in place.

c.

The inside of the termination tee must be a

minimum of 14 inches from outside wall.
See Figure 5 for a correctly completed in*
stallation.

Caution:

Do not step on, sit or place any weight on

termination tee. If termination tee Is dis­
lodged, furnace may not operate.

WARNlNOt

DO NOT STEP ON, HIT OR PLACE ANY

WEIGHT ON TERMINATION TEE. IF TERMINATION

TEE IS MISHANDLED, VENT SYSTEM MAY BECOME

DISCONNECTED

AT

FURNACE

ALLOWING

FLUE

PRODUCTS TO COLLECT IN STRUCTURE DURING
USE, RESULTING IN INJURY OR DEATH.

2

. VKRTICAL VENTING

When using high temperature plastic pipe, vent system
must be dedicated and is not to be common vented with
any other appliance.

WARNINGS

COMMON VENTING COULD ALLOW

PRODUCTS

OF

COMBUSTION

TO

ESCAPE

THROUGH OTHER APPLIANCE CONNECTED TO
SAME VENT. THIS COULD RESULT IN COMBUSTION
PRODUCTS COLLECTING IN STRUCTURE DURING
USE, RESULTING IN INJURY OR DEATH.

A. Starting Vant System

You may use high temperature plastic pipe to verti­
cally vent this induced-draft furnace. Use instructions

in horizontal venting section for proper air space

clearances to combustible materials, pipe sizing,
allowable runs,joining,cutting, condensate disposal,
inducer transition, and plaustic vent transition kit. See

Figures 6 and 7 for correctly started vertical vent

systems.

3" and 4'* Thimble

Figure 6

67