Mufti-Story Vent Systems

Use Individual Vent

for Top Floor Appliance

if Connector Requirement
for Rise or Total Height
Cannot be Met

Use Vent Connector

Table

Top Floor Appliance

Avaitabte Total

Height for Top
Floor Appliance

r I -]

r—

t

Rise

Available Total

Height for Third

Floor Appliance

Use Vent Connector

Table

Third Floor Appliance

r-i—

=

P—

I

1

Rise

!

-f-~= up

Available Total

Height for Second

Roor Appliance

Use Vent Connector

Table

Second Root Appliance

"

1

* Rise

Tee With Cap Optional

Rrst Roor Appliance

Listed Cap

Use Available Total Height for
Top Floor Appliance and
Combined InpiAof All

Appliances on Common Vent

Third Connection Tee *

Available Total Height for
Third Floor Appliance and
Combined Input of Three
Appliances (If Top Floor
Appliance is Not Connected,

Measure Total Height to
Vent Top)

Second Connection Tee

Use Available Total Height

for Second Floor Appliance
and Combined Heat Input

of Two Appliances

First Connection Tee *

Design Vent Connector for First
Floor Appliance as an Individual

Vent of This Total Height for

Input of Rrst Floor Appliance

* Each Interconnection Tee is Same Size as

Segment of Common Vent Directly Above