Vertical termination, 90° h, 45° v – Continental BCDV48N User Manual

Page 13: 90° v

Advertising
background image

W415-0327 / B / 12.07.07

13

H

1

VERTICAL TERMINATION

For vent confi gurations requiring more than one 45º and one 90°
elbow , the following formulas apply:

Formula 1: H

T

< 3V

T

Formula 2: H

T

+ V

T

< 40 feet

Example 4:

when (H

T

) > (V

T

)

Simple venting confi gurations

See graph to determine the required vertical rise V

T

for the required

horizontal run H

T

.

V

1

= 1 ft

V

2

= 1.5 ft

V

T

= V

1

+ V

2

= 1 + 1.5 = 2.5 ft

H

1

=

6

ft

H

2

=

2

ft

H

R

=

H

1

+ H

2

= 6 + 2 = 8 ft

H

O

= .03 (one 45º elbow + three 90º elbow - 135º)

= .03(45 + 90 + 90 + 90 - 135) = 5.4 ft

H

T

=

H

R

+ H

O

= 8 + 5.4 = 13.4 ft

H

T

+ V

T

= 13.4 + 2.5 = 15.9 ft

Formula 1:

H

T

< 3V

T

3V

T

= 3 x 2.5 = 7.5 ft

13.4 > 7.5

Since this formula is not met, this vent confi guration is unac-
ceptable
.

Formula 2:

H

T

+ V

T

< 40 feet

15.9

<

40

Since only formula 2 is met, this vent confi guration is unac-
ceptable and a new fi replace location or vent confi guration will
need to be established to satisfy both formulas.

Example 5:

V

1

= 1.5 ft

V

2

= 8 ft

V

T

= V

1

+ V

2

= 1.5 + 8= 9.5 ft

H

1

=

1

ft

H

2

=

1

ft

H

3

=

10.75

ft

H

R

=

H

1

+ H

2

+ H

3

= 1 + 1 + 10.75 = 12.75 ft

H

O

= .03 (three 90° elbows + two 45° elbow - 135°)

= .03(90 + 90 + 90 + 45 + 45 - 135) = 6.75 ft

H

T

=

H

R

+ H

O

= 12.75 + 6.75 = 19.5 ft

H

T

+ V

T

= 19.5 + 4.5= 29 ft

Formula 1:

H

T

< 3V

T

3V

T

= 3 x 9.5 = 28.5 ft

19.5 < 28.5

Formula 2:

H

T

+ V

T

< 40 feet

29

<

40

Since both formulas are met, this vent confi guration is accept-
able.

REQUIRED
VERTICAL
R I S E I N
FEET (V

T

)

HORIZONTAL VENT RUN PLUS OFFSET IN FEET (H

T

)

FIGURE 14

FIGURE 12

45°

45°

90°

90°

H

1

H

2

90°

H

3

The shaded area within the lines represents acceptable values
for H

T

and V

T

.

90°

FIGURE 13

45°

V

1

90°

V

2

90°

H

2

V

2

V

1

Advertising