Proceed once the vent installation is complete.

NOTE: All gas connections must be contained within the fi replace
when complete.

1. Move the fi replace into position and secure to the fl oor through

the 1/4" holes located at either side of the base.

2. The fi replace is designed to accept 3/8" gas supply line. The

fi replace is equipped with a 3/8" manual shut-off valve.

3. Connect the gas supply in accordance to local codes. In the

absence thereof, install according to the National Installation Code.

4. When fl exing any gas line, support the gas valve so that the lines

are not bent or kinked.

5. Check for gas leaks by brushing on a soap and water solution.

DO NOT USE OPEN FLAME.

Purge all gas lines with the glass door of the stove removed.
Assure that a continuous gas fl ow is at the burner before re-in-
stalling the door.

GAS INSTALLATION

Conversion Kits

The mobile home appliance is fi eld convertible between Natural Gas
(NG) and Propane (LP).
To convert from one gas to another consult your Continental dealer/
distributor.

Note: In order to avoid the possibility of exposed insulation or vapour
barrier coming in contact with the fi replace body, it is recommended that
the walls of the fi replace enclosure be “fi nished” (ie: drywall/sheetrock),
as you would fi nish any other outside wall of a home. This will ensure
that clearance to combustibles is maintained within the cavity.

It is best to frame your fi replace after it is positioned and the vent system
is installed. Use 2x4's and frame to local building codes.

It is not necessary to install a hearth extension with this fi replace
system.

When roughing in the fi replace, raise the fi replace to accommodate
for the thickness of the fi nished fl oor materials, i.e. tile, carpeting,
hard wood, which if not planned for will interfere with the opening of
the lower access door and the installation of many decorative fl ashing
accessories.

This Mobile/Manufactured Home Listed appliance comes factory
equipped with a means to secure the unit. The fi replace is equipped
with two 1/4” diameter holes located in the front left and right corners
of the base. For mobile home installations, the fi replace must be fas-
tened in place. Use #10 hex head screws, inserted through the holes
in the base to secure. Always turn off the pilot and the fuel supply at
the source, prior to moving the mobile home.

After moving the mobile home and prior to lighting the fi replace, ensure
that the logs are positioned correctly.

MOBILE HOME INSTALLATION

FRAMING

This appliance is certifi ed to be installed as an OEM (Original Equip-
ment Manufacturer) installation in a manufactured home or mobile
home and must be installed in accordance with the manufacturer’s
instructions and the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States or the
Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s) of gas indicated on
the rating plate. A conversion kit is supplied with the mobile home
appliance.

This appliance is certifi ed to be installed in an aftermarket perma-
nently located, manufactured (mobile) home, where not prohibited
by local codes.

This fi replace is only for use with the type of gas indicated on the
rating plate. This fi replace is not convertible for use with other gases,
unless a certifi ed kit is used.

51

1

/

2

"

48

1

/

2

"

72

11

/

16

"

FIGURE 34

Objects placed in front of the fi replace should be kept a minimum of
48" away from the front face.

Combustible materials may be installed fl ush with the front of the fi re-
place but must not cover any of the black face areas of the fi replace.
Non-combustible material (brick, stone or ceramic tile) may protrude
in these areas.

For ease of accessibility, an optional remote wall switch may be installed
in a convenient location. A 20’ length of millivolt wire is connected to
the gas valve for the wall switch. However if a greater length is required
route 2-strand (solid core) millivolt wire through the electrical hole lo-
cated at the bottom left side of the unit. The recommended maximum
lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14 gauge

100 feet

16 gauge

60 feet

18 gauge

40 feet

Attach the two leads to terminals 1 and 3 located on the gas valve.

OPTIONAL WALL SWITCH

INSTALLATION

FIGURE 33

Minimum clearance to combustible construction
from fi replace and vent surfaces:

Framing 0"

to

stand-offs

Finishing

0" to rear, sides and bottom

Non-combustible fi nishing

8" to top

All around the vent pipe

2"

Recessed depth

23"

Enclosure top

55" from bottom of unit

Clearance to ceiling

84" from bottom of unit

FIGURES 35a-b