MINIMUM MANTEL AND ENCLOSURE

CLEARANCES

Combustible mantel clearance can vary according to the mantel depth.
Use the graph to help evaluate the clearance needed. Curtains, above
the fi replace, must not be positioned lower than the 2" distance re-
quired for the 2" combustible mantel. These same requirements ap-
ply to any combustibles protruding on either side of the fireplace.

The fi replace requires a minimum enclosure height of 55“. For tempera-
ture requirements, the enclosure space around and above the fi replace
must be left unobstructed.

FIGURE 36

FIGURE 38b

FIGURE 38a

FIGURE 38c

FIGURES 37

* See venting section

Minimum clearance to combustible construction from
fi replace and vent surfaces:

Framing 0"

to

stand-offs

Finishing

0" to rear, sides and bottom

Non-combustible fi nishing

8" to top

All around the vent pipe

2"

Recessed depth

23"

Enclosure top

55" from bottom of unit

Clearance to ceiling

84" from bottom of unit