Adjustments – Continental BCDV48N User Manual

Page 23

Advertising
background image

W415-0327 / B / 12.07.07

23

VENTURI COVER

Adjust the pilot screw to provide properly sized fl ame. Turn in a
clockwise direction to reduce the gas fl ow.

Air shutters have been factory set open according to the chart
below:

These settings are for the maximum horizontal vent run.- Adjust-
ment may be required depending on fuel type, vent confi guration
and altitude.

Closing the air shutter will cause a more yellow fl ame, but can lead
to carboning. Opening the air shutter will cause a more blue fl ame,
but can cause fl ame lifting from the burner ports. The fl ame may not
appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame
colour to be established.

Air shutter adjustment must only be done by a qualified

installer!

To access the air shutter, remove the two screws that secure the cover
to the air housing, taking care not to damage the gasket.

NOTE: Ensure burner is seated onto orifi ce

FIGURE 56

FIGURE 55

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

VENTURI ADJUSTMENT

FIGURE 58

FRONT REAR

NG

1

/

8

"

7

/

32

"

LP

3

/

16

"

3

/

8

"

FIGURE 57

Advertising