Demo pattern settings and cautions – Akai Multi Video Processor RMD-V3104U User Manual

Page 31

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

MVP MANUAL

8. DEMO PATTERN SETTINGS AND CAUTIONS

The MVP does not have an RMD-V3216 type DEMO switch, but 2x2 enlarged screen automatic display is pos­

sible by reading the input selector switch (OPTION/V IN) when the power is turned on and executing the com­

mand corresponding to that setting.

Because

of

this,

upon

shipment

from

the

factory

command

examples

for

displaying

the

MVP

2x2

enlarged

screens have been written into the demonstration switch No. 8 and No. 9 areas, which were user program areas

on the RMD-V3216.

Switch No. 8 contains the command example for displaying 2x2 enlarged screens for the OPTION input picture

(A input).

Switch No. 9 contains the command example for displaying 2x2 enlarged screens for the V IN input picture (C

input).

2x2 enlarged screens may not be displayed if the contents of demo No. 8 and demo No. 9 are replaced. If this

happens, reset the factory defaults.

The commands written into the set upon shipment from the factory and the procedure for writing the com­

mands are described below.

!

&NO011

&NO121

&NO212

&NO322

[8

W3

M11A22

]

[9

W3

M11C12

]

Start the command interpreter and input the following commands.

Matrix screen

number setting . . . . . . . . . Set VOUT1

matrix coordinate to 11.

Matrix screen

number setting. . . . . . Set VOUT2

matrix coordinate to 21.

Matrix screen

number setting. . . . . . Set VOUT3

matrix coordinate to 12.

Matrix screen

number setting. . . . . . Set VOUT4

matrix coordinate to 22.

Write in the command example for 2x2 enlargement of the A input to demonstration switch No.

8.

: Write in the command example for 2x2 enlargement of the C input to demonstration switch No. 9.

End.

The RM-V1000NU's internal MVP assembly (AWU1014-) uses slots A and B, but this set uses slots A and C.

Note that because of this the M command setting is different.

157