Locate - 30

UtiliGuard™ Series Operator’s Manual

Locate Active Signals

CMW

®

Locate Active Signals

Setup

Follow setup procedures for the type of locating
you will be doing: direct connection, induction
clamp, connecting to live power with live power
adapter, or broadcast induction. For all types of
active location that require leads, connect leads
to transmitter at connector (2). Keep connector
covered when not in use. When it is necessary to
connect to external power, use connector (1).

Induction Clamp

To set up transmitter for use with induction
clamp:

1.

Plug cable into transmitter.

2.

Place clamp around cable.

3.

Turn on transmitter.

4.

Check battery level.

Jobsite hazards could cause death or serious injury. Use

correct equipment and work methods. Use and maintain proper safety
equipment.

NOTICE: Electric shock or equipment damage can result if transmitter is connected to live cable.
Contact qualified utility personnel and follow all standards and requirements for disconnecting and
grounding cables.