Utiliguard™ series operator’s manual – Ditch Witch UtiliGuard User Manual
Page 44
Advertising
UtiliGuard™ Series Operator’s Manual
Locate - 43
Locate Beacon Signal
CMW
®
6.
When the beacon is correctly located, a
diamond (1) will form in the center of the
compass, the exterior arrows (2) will appear,
and the depth reading will display.
7.
If operating in Manual depth, press the Depth
key to estimate depth.
8.
Continue to track the beacon and observe
depth readings. Mark pipe location with paint.
NOTICE: When estimating depth with
a beacon in nonmetallic pipe, depth
shown will be to the center of the
beacon, not to the top of the pipe.
Advertising