UtiliGuard™ Series Operator’s Manual

Locate - 31

Locate Active Signals

CMW

®

Direct Connection

To set up transmitter for direct connection:

1.

Carefully push ground stake (3) into ground.

2.

Plug cable into transmitter (2).

3.

Connect black lead to ground stake.

4.

Connect red lead to cable (1).

Note: If using dual location, connect white lead to the additional cable to be located.

5.

Turn on transmitter and check battery level.

Jobsite hazards could cause death or serious injury. Use

correct equipment and work methods. Use and maintain proper safety
equipment.

NOTICE:

Electric shock or equipment damage can result if transmitter is connected to live cable. Contact
qualified utility personnel and follow all standards and requirements for disconnecting and grounding
cables.

A built-in circuit breaker will automatically disable transmitter when leads are connected to a live
cable. Display will flash and transmitter will beep. Turn off transmitter and disconnect from cable to
reset breaker.

NOTICE: Turn off transmitter when connecting or moving ground stake.