14

SPARK PLUG
See parts breakdown for recommended spark plug.
1. Check spark plug at the beginning of each season.
2. Disconnect the spark plug cap, and clean any debris from

around the spark plug area.

3. Remove spark plug and replace if any of the following occur;

pitted electrodes, burned electrodes, cracked porcelain, or

deposits around electrodes.

4. After analysis, seat spark plug and tighten with spark plug

wrench.

• Reinstall original spark plug, tighten additional 1/2 turn.
• Installing new spark plug, adjust spark plug gap to .028” and

tighten additional 1/8 – 1/4 turn .

NOTE: Loose spark plug may overheat and damage engine.

Over tightened spark plug may damage threads in the

cylinder head.

CARBURETOR
Never tamper with factory setting of the carburetor.

TRANSPORTING YOUR EARTH AUGER

1. Never transport engine inside an enclosed space or vehicle.

Fuel or fuel vapors may ignite causing serious injury or death.

2. If fuel is present in the fuel tank, transport in an open vehicle

in an upright position.

3. If an enclosed vehicle must be used, remove gas into an ap-

proved red fuel container. DO NOT siphon by mouth.

4. Run engine to use up the fuel in the carburetor and fuel tank.

Always run engine in a well ventilated area.

5. Wipe away any spilled fuel from engine and earth auger. Allow

to dry.

LONG-TERM STORAGE

(30 DAYS OR MORE WITHOUT USE)
If your earth auger will not be used for more than one month,

prepare it for long term storage.

STEPS FOR LONG-TERM STORAGE
1. Add fuel stabilizer according to manufacturer’s instructions.
2. Run engine for 10-15 minutes to ensure that the stabilizer

reaches the carburetor.

3. Remove the remainder of the fuel from the gas tank into an

approved fuel container.

4. Remove auger from powerhead and apply a thin layer of

grease to the output shaft of the transmission.

5. Store auger and powerhead (engine) in a vertical position.
6. Remove all debris from auger and powerhead (engine).

CAUTION

TO AVOID INJURY OR DEATH, NEVER SIPHON FUEL BY

MOUTH.
NEVER STORE EARTH AUGER WITH FUEL IN THE GAS

TANK INSIDE AN ENCLOSED AREA OR BUILDING.
TO PREVENT ACCIDENTAL STARTING:

ENGINE MUST BE TURNED OFF AND COOL, AND

SPARK PLUG WIRE MUST BE REMOVED FROM SPARK

PLUG BEFORE CHECKING AND ADJUSTING ENGINE

OR EQUIPMENT.
MAINTENANCE AND REPAIR ON THE ENGINE AND AU-

GER MUST ALWAYS BE DONE BY AN ADULT.
ENGINE MUST BE SHUT-OFF, COOL, AND SPARK PLUG

WIRE REMOVED BEFORE ANY REPAIR OR MAINTE-

NANCE CAN BE DONE.

TROUBLESHOOTING AND REPAIR

At Earthquake, we build quality and durability into the design of

our products; but no amount of careful design by us, and careful

maintenance by you, can guarantee a repair-free life for your

Earthquake powerhead. Most repairs will be minor, and easily

fixed by following the suggestions in the troubleshooting guide

in this manual.

The troubleshooting guide will help you pinpoint the causes of

common problems and identify remedies.

For more complicated repairs, you may want to rely on an

authorized service center or Earthquake. A parts breakdown is

located toward the end of this manual.

We will always be glad to answer any questions you have, or

help you find suitable assistance. To order parts or inquire about

warranty, call or e-mail us using the contact information found

under "Ordering Replacement Parts".

ORDERING REPLACEMENT PARTS

Parts can be obtained directly from the factory. To order parts

visit www.getearthquake.com or call 1-800-345-6007.
For other general questions, you can e-mail us at [email protected].

IN CASE OF A SERVICE PROBLEM, DO NOT SEND PRODUCT

BACK TO RETAILER. CONTACT EARTHQUAKE AT 800-345-

6007.
Include the following information with your order:
1) Part numbers
2) Part description
3) Quantity
4) Model number and serial number

Advertising