Configuring initiate lns uplink properties, Configuring time settings, Configuring initiate lns uplink properties -21 – Echelon i.LON 100 e2 Internet Server User Manual

Page 63: Configuring time settings -21

Advertising
background image

i.LON 100 Internet Server User’s Guide

4-21

Delay Time Between Two

Retries

This option is not supported for LNS 3,

Service Pack 8, Update 1, and earlier.
This option is only available if Initiate LNS

Uplink When IP Address Changes is
checked. If the i.LON 100 attempts to inform

the xDriver of an IP address change and is not

successful, this is the amount of time before
another attempt is made.

Maximum Retry Time

This option is not supported for LNS 3,

Service Pack 8, Update 1, and earlier.
This option is only available if Initiate LNS

Uplink When IP Address Changes is
checked. The amount of time, in minutes, for

which the i.LON 10 Ethernet Adapter will

attempt to inform the server of an IP address
change.

Initiate LNS Uplink
When Any Explicit

Message is Received

Set this option to initiate an uplink connection
from the i.LON 100 to the LNS Server whenever

an explicit message is sent to the host. If this

option is cleared, explicit messages for the host
will be held until a connection is established. By

default, this option is cleared.

Initiate Only When
Explicit Message Code is

in Range

Set this option to initiate an uplink connection
from the i.LON 100 to the LNS Server whenever

an explicit message with a message code within
the specified range is sent to the host. If this

option is cleared, explicit messages for the host

outside the specified range will be held until a
connection is established. By default, this option

is cleared.

Configuring Initiate LNS Uplink Properties

Set these options to determine when the i.LON 100 will attempt to initiate an
uplink connection to the LNS Server based on a network variable message for the

host. If an update is received that is not configured to establish an uplink
connection, the update will be held until a connection is established. By default,

all of these options are cleared (i.e. the i.LON 100 will never attempt to establish

an uplink connection as a result of a network variable message).
Click Submit to save the changes you have made to this Web page. Click Reset

to set all fields on this Web page back to the values they had when you opened

the page.

Configuring Time Settings

The i.LON 100 has a real-time clock. The time for this clock can be set manually

using the Time Web page or synchronized to an SNTP time server as described
in Configuring the Time Service, earlier in this chapter.
To view and set the time, hover your mouse cursor over Setup and select Time
from the dropdown menu. The Time Web page opens, as shown in the following

figure:

Advertising