ENMET MX-32 User Manual

Page 12

Advertising
background image

ENMET Corporation

MX32

E

NGUARD

8

Table 1: wiring terminal

Ref
Label

Terminal
Label

Wiring

P

J1

Input, AC high

N

J2

Input, AC neutral

J3

Ground

0

J4

Input, DC minus

+24V

J5

Input, DC positive

DEF

J6

Fault relay*

J7

Fault relay*

C1

J8

Channel 1, Sensor signal – (See Table 2, 3 for 2 or 3 wire S/T)

C2

J9

Channel 1, Sensor ground if used (See Table 2, 3 for 2 or 3 wire S/T)

C3

J10

Channel 1, Sensor + (See Table 2, 3 for 2 or 3 wire S/T)

RL1

J11

Channel 1, Alarm 1 relay*

J12

Channel 1, Alarm 1 relay*

RL2

J13

Channel 1, Alarm 2 relay*

J14

Channel 1, Alarm 2 relay*

C1

J15

Channel 2, Sensor signal – (See Table 2, 3 for 2 or 3 wire S/T)

C2

J16

Channel 2, Sensor ground if used (See Table 2, 3 for 2 or 3 wire S/T)

C3

J17

Channel 2, Sensor + (See Table 2, 3 for 2 or 3 wire S/T)

RL1

J18

Channel 2, Alarm 1 relay*

J19

Channel 2, Alarm 1 relay*

RL2

J20

Channel 2, Alarm 2 relay*

J21

Channel 2, Alarm 2 relay*

* See Table 1a for setting relays to NO or NC operation.

4-20 Sensor/Transmitter

Sensor/Transmitters are connected to positions C1, C2 and C3 on each channel terminal strip. Connections are shown
in Table 2 for two wire S/T and Table 3 for three wire S/T. See Figure 5 for location of channel terminal strips.

Table 2: Wiring for a Two Wire S/T

Table 3: Wiring for a Three Wire S/T

Two Wire Sensor/Transmitter

Three wire Sensor/Transmitter

C1

Signal minus (–

–)

C1

Signal

C2

Not used

C2

Ground

C3

Signal plus, +24

V

DC

power

C3

+24

V

DC

power

Advertising