Pinout assignments 103, Appendix – Hatteland Display 26 inch - HD 26T21 MMC (Widescreen) User Manual

Page 103

Advertising
background image

Pinout Assignments

103

IND100241-19

Appendix

Serial COM RS-232 non-isolated, 9-pin DSUB Male

1 2 3 4 5

6 7 8 9

PIN 01 DCD

Data Carrier Detect

PIN 02 RxD

Receive Data

PIN 03 TxD

Transmit Data

PIN 04 DTR

Data Terminal Ready

PIN 05 GND

Signal Ground

PIN 06 DSR

Data Set Ready

PIN 07 RTS

Request To Send

PIN 08 CTS

Clear To Send

PIN 09 RI

Ring Indicator

Analog RGB/VGA, 15-pin DSUB High Density Female

5 4 3 2 1

15 14 13 12 11

10 9 8 7 6

PIN 01 RED

Red, analog

PIN 02 GREEN

Green, analog

PIN 03 BLUE

Blue, analog

PIN 04 ID2/RES

Reserved for monitor ID bit 2 (grounded)

PIN 05 GND

Digital ground

PIN 06 RED_RTN

Analog ground red

PIN 07 GREEN_RTN Analog ground green

PIN 08 BLUE_RTN

Analog ground blue

PIN 09 KEY/PWR

+5V power supply for DDC (optional)

PIN 10 GND

Digital ground

PIN 11 ID0/RES

Reserved for monitor ID bit 0 (grounded)

PIN 12 ID1/SDA

DDC serial data

PIN 13 HSYNC.

Horizontal sync or composite sync, input

PIN 14 VSYNC.

Vertical sync, input

PIN 15 ID3/SCL

DDC serial clock

Serial COM RS-485/RS-422, 9-pin DSUB Male

“Full Duplex Mode*

1 2 3 4 5

6 7 8 9

PIN 01 TxD-

Transmit Data Negative

PIN 02 TxD+ Transmit Data Positive

PIN 03 RxD+ Receive Data Positive

PIN 04 RxD- Receive Data Negative

PIN 05 GND Signal Ground

PIN 06 N/C

No internal connection

PIN 07 N/C

No internal connection

PIN 08 N/C

No internal connection

PIN 09 N/C

No internal connection

*Master only. ECHO not supported.

Serial COM RS-485/RS-422, 9-pin DSUB Male

“Half Duplex Mode*

1 2 3 4 5

6 7 8 9

PIN 01 Res.

Reserved, do not connect

PIN 02 Res.

Reserved, do not connect

PIN 03 Data+ Data Positive

PIN 04 Data- Data Negative

PIN 05 GND Signal Ground

PIN 06 N/C

No internal connection

PIN 07 N/C

No internal connection

PIN 08 N/C

No internal connection

PIN 09 N/C

No internal connection

*ECHO not supported.

Half Duplex Confi guration: Via Hatteland Display API.

Flow control: Via RTS signal (controlled by user application).

8-pin RJ-45 10/100Mbps LAN/Ethernet

PCA100298-1 / HT 00274 OPT-A1

1 2 3 4 5 6 7 8

Pin 01 - TDP Transmit Differential Pair (Positive)

Pin 02 - TDN Transmit Differential Pair (Negative)

Pin 03 - RDP Receive Differential Pair (Positive)

Pin 04 - NC

Not Connected

Pin 05 - NC

Not Connected

Pin 06 - RDN Receive Differential Pair (Negative)

Pin 07 - NC

Not Connected

Pin 08 - NC

Not Connected

Advertising