WARNING AND SAFETY NOTES

As default this charger will be set to typical user setting when it is connected a 12V
battery for the first time. The screen displays the following information in sequence and
the user can charge the parameter on each screen.

If you need to alter the parameter value in the program, press 'Start/Enter' key to make it
blink then change the value with 'INC' or 'DEC' key. The value will be stored by pressing
'Start/Enter' key once.

CHARGING OF LITHIUM BATTERY

INDIVIDUAL CELL CONNECTION DIAGRAM(PIN-ASSIGNMENT OF 8-PIN)

The value on the left side of the second lines sets the charge
current. The value on the right side of the second lines sets the
battery pack's voltage. After setting current and voltage, press
STAR/ENTER for more than 3 seconds to start the process.

This displays the number of cells you set up and the processor
detects. 'R' shows the number of cells detected by the charger and
'S' is the number of cells set by you at the previous screen. If both
numbers are identical you can start charging by press
START/ENTER button. If not, press BATT TYPE/STOP button to go
back to previous screen to carefully check the number of cells of
the battery pack before going ahead.

This screen shows the real-time status during charge process.
Press BATT TPE/STOP key once to stop the charge process.