B6 Twins incorporates a variety of functions for the systems to varify processes and the state of
the electronics. In case of an error the screen will display the cause of error and emit an audible
sound.

Delta-peak sensitivity: The automatic charge termination program based on the principle of the
Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process
will be terminated automatically.

SPECIAL FEATURES

WARNING AND ERROR INFORMATION

Maximum safety

Automatic charging current limit

You can set up the upper limit of the charging current when charging your NiCd or NiMH battery;
it is useful for the NiMH battery of low impedance and capacity in the 'AUTO' charging mode.

Capacity limit

The charging capacity is always calculated as the charging current multiplied by time. If the
charging capacity exceeds the limit, the process will be terminated automatically when you set
the maximum value.

Temperature threshold*

The battery's internal chemical reaction will cause the temperature of the battery to rise. If the
temperature limit is reached, the process will be terminated.

*This function is available by connecting optional temperature probe, which is not included in our package.

Processing time limit

You can also limit the maximum process time to avoid any possible defect.

Input power monitoring

To protect the car battery used as DC input power from being damaged, its voltage keeps being
Monitored. If it drops below the lower limit, the process will be ended automatically.

Date store/load

The maximum five batteries' date can be stored for user's convenience. You can keep the date
pertaining to program setting of the battery of continuous charging or discharging. Users can
call out these date at anytime without any special program setting.

WARNING AND ERROR INFORMATION

Incorrect polarity connected.

Erroneous selection of voltage of Lithium pack, please check the voltage
of the battery pack.

The voltage of the battery pack has been selected incorrectly!

The voltage is lower than which is set. Please check the number of cells
in the batter pack.

Battery connection is interrupted.

Short-circuit of the output termination.

The charger has malfunctioned for some reason. Seek professional
advice.