Warning, Data storage program – Imaxrc B6-TWINS User Manual

Page 7

Advertising
background image

This diagram shows the correct way to connect your battery to the

B6 Twins

charger while in

the Balance charge program mode only.

LITHUM POLYMER BALANCE CHARGE PROGRAM

CONNECTION DIAGRAM

DATA STORAGE PROGRAM

LITHUM POLYMER BALANCE CHARGE PROGRAM CONNECTION DIAGRAM

*The main battery leads must be connected along with the balance lead connector as shown before charging
your battery.

Failure to connect will damage this charger. The right approach is as follows:

If using crocodile clips shown in above diagram, make sure they are unable to touch
Together!

WARNING:

WARNING:

DATA STORAGE PROGRAM

Setting of the parameter in the screen will not affect the charge and
discharge process. They just present the specification of the battery.
The example is NiMH battery pack, including 12 cells, the capacity is
3000mAh.

Set up the charge current in the manual mode, or current limit in the
auto mode. Press INC and DEC key simultaneously to make the
current field blink to switch charge mode.

Set up the discharge current and final voltage.

Set up the charge/discharge sequence and cycle number.

Saving the data

For your convenience, B6 Twins has a date storage and load program. It can store five
battery date representing the respective specifications of batteries. You can call back the data
when charging or discharging without setting up the program again. Press START/ENTER key
to make it blink, and use INC or DEC to set up the parameter.