Advanced programming – Konig Electronic Wireless alarm system User Manual

Page 24

Advertising
background image

- 24 -

System Armed (Alarm Mode)

If a zone is set to “Beep”, the control panel will give entry / exit delay.
If a zone is set to “Alarm”, the siren will sound immediately without entry delay

- Alarm Mode (System Armed): If a sensor is triggered (i.e. opening a door) with
the alarm setting on, the siren will sound immediately without entry delay, it is
called “Instant Alarm”. The siren will not stop until the siren timeout or a valid
password is entered. Control panel will call the emergency phone numbers to
notify the users of the alarm situation.

When a sensor is triggered, there are 4 options:

ZONE SETTING

OPERATING MODE

BEEP

ALARM

Disarmed (Alert)

1) Beep

2) Alarm sounds immediately

Armed (Alarm)

3) Entry / Exit Delay

4) Alarm sounds and calls

preprogrammed phone
numbers immediately

Factory Default: All zones were programmed to Beep at the factory.

ADVANCED PROGRAMMING

Y

-

Caution:

It is not recommended to program an outdoor sensor to Alarm mode, which may cause
false alarm. For outdoor sensors, they should be programmed into an Alert Zone,
please refer to page 30 for details.

Advertising