4 discharge time, D. set timer, 5 cutoff voltage – Lamar Technologies CA 1550 User Manual

Page 20

Advertising
background image

4. OPERATING GUIDE - DISCHARGING

4.4 DISCHARGE TIME

4.4.1 TIMER UNIT SETTING

The CA-1550 has a built in timer, allowing discharge time settings from 1 to 999

minutes.

4.4.2 DISCHARGE TIME SETTING

The discharge time is usually set to 60 minutes, after which a pass/reject signal is

given based on whether the battery reached the cutoff voltage or not.

To determine the full capacity of the battery a longer time can be set (several

hours). The CA-1550 will then continue the discharge test only until the cutoff

voltage has been reached. The timer, cutoff voltage and discharge current displays

will freeze at this point. The capacity can be calculated as the product of the

discharge current and the time passed until the voltage cutoff was reached.

Refer to your battery manufacturer’s maintenance manual for the

recommended discharge times.

D. SET TIMER

Set the timer by pushing the up/down buttons

to the required discharge time (usually 60

minutes)

CAUTION. For lead-acid batteries the

time and voltage cutoff should be set with

caution. If discharge continues too far

beyond the point of exhaustion it may be

harmful to the battery, unless the battery is

soon to be recharged.

4.5 CUTOFF VOLTAGE

The CA-1550 will automatically stop the discharge test when the cutoff voltage has

been reached. The cutoff voltage is set so that if the battery voltage is higher than

the cutoff voltage when the discharge time has expired, the battery has passed the

capacity test.

CA-1550 CHARGER / ANALYZER - OPERATING MANUAL V1.2

Page 18

Advertising