7. SPECIFICATIONS

7 SPECIFICATIONS

AC Line Input:

115 volts

10%, 50/60Hz, 14 amperes or

230 volts

10%, 50/60 Hz, 7 amperes

(selectable inside unit)

DC Discharge Current: Capacity

0 - 50 amperes adjustable current

Accuracy

 

2% from discharge initiation to cut-off

Constant Current

Capacity

0 - 25 amperes adjustable, 35 volt limit

Charge Mode:

Accuracy

 

2% from charge initiation to completion

Constant Potential

Setting

Selectable 14.5/28.6 volts, 25 ampere limit

Charge Mode:

Accuracy

 

2% from charge initiation to completion

Timer:

Setting

Adjustable from 0 to 999.9 units

Units

Selectable on front of timer from 0.1 to 999.9

Accuracy

 

1.0%

Digital Meter Accuracy: Voltmeter

 

0.2 volts

Ammeter

 

0.2 amperes

Cooling:

Fan cooled

Housing:

Compact transit case

Outer Dimensions:

Height

14 in. (356 mm)

Depth

15 in. (381 mm)

Width

10 ¼ in. (260 mm)

AC Line Cord:

AWG 14 3 wire grounded
6 ft long with 115 volt 15 ampere plug
User required to change to 230 volt plug

DC Discharge Cable:

4 ft Terminal w/Quick Disconnect Adaptor

Weight:

Net 53 lbs. (24.1 kg)
Shipping 58 lbs. (26.3 kg)

Fuses:

AC line

20A/250V, type MDA 1 ¼ x ¼

Charge line

40A/32V, type MDL 1 ¼ x ¼

Discharge

70A/32V, type Lfuse 0498070

Adaptors Included:

Alligator Clip Connector, 24V Aircraft Battery Connector,

and Ring Terminal Connector