5. CALIBRATION AND MAINTENANCE

F. SWITCH ON MAINS POWER

Turn on the AC on-off/reset power switch.

The voltmeter reads battery terminal voltage,

the ammeter reads zero. The timer reads 0’s

and its red LED is off. The Charge Mode Lamp

indicator is illuminated.

G. SET CHARGE CURRENT

Turn the Ampere Adjust knob until

approximately 15 amperes has been reached.

The charge current is displayed on the

ammeter as the current is being adjusted.

NOTE: If the battery is already significantly

charged it may be hard to reach a 15 ampere

current.

H. CONNECT EXTERNAL

VOLTMETER

Set the voltmeter to a DC millivolt range.

Connect the external digital voltmeter into the

ammeter calibration points.

I. COMPARE AMPERE READINGS

Compare the CA-1550 digital ammeter

reading with the external calibrated

millivoltmeter. The external meter reads the

millivolt drop across a 50 ampere/50 millivolt

shunt. Every millivolt read on the external

millivoltmeter represents 1 ampere. The

readings should be within ± 0.2 millivolts

(amperes).

a. If readings differ less than ± 0.2 millivolts

(amperes), the ammeter is accurately

calibrated. Turn AC power off and disconnect battery.