OmniLink 5000 Feed Manual

December 13, 1999

2.4

Manual Rev 2.3

2.5

Coe ServoMaster Interface

The connection to a Coe ServoMaster Feed uses

two cables - an adapter cable to go from a telephone
type connector on the operator interface of the
ServoMaster to a DB-9 connector, and a longer
cable to go from the DB-9 connector to the Link
operator terminal.

Table 2.3

Coe ServoMaster Connections

(Adapter Cable) Link PN 107921

DB-9
Female

Function

Coe
Telephone
Jack

Pin 1
(GND)

Ground

Pins 3 and 4

Pin 2
(RXD)

Transmit data to
feed

Pin 5

Pin 3
(TXD)

Receive data
from feed

Pin 2

Table 2.4

Coe ServoMaster Connections

(Main Cable) Link PN 105721

OmniLink
Feed Port

Function / Color

DB-9
Male

Pin 1
(GND)

Ground (WHITE)

Pin 5

Pin 2
(RXD)

Receive data from
feed (BLACK)

Pin 3

Pin 3
(TXD)

Transmit data to
feed (RED)

Pin 2

Notes:

‚

The telephone jack is located on the back of the
Coe operator interface terminal

‚

The feed communications settings (as set in the
Coe operator terminal) should be 9600 Baud, 7
data bits, Odd parity, 1 stop bit.