2.5

Manual Rev 2.3

2.6

CWP ServoDial II Interface

The connection to a CWP ServoDial II feed is as

follows:

Table 2.5

CWP ServoDial II Connections

Link PN 107819

OmniLink
Feed Port

Function / Color

CWP

Pin 1
(GND)

Ground (WHITE)

Pin 7

Pin 2
(RXD)

Receive data from
feed (BLACK)

Pin 3

Pin 3
(TXD)

Transmit data to
feed (RED)

Pin 2

Pins 4 and
5
Jumpered
Together

Notes:

‚

The feed Panel/Remote switch must be in the
Remote position for the feed to receive data.

‚

The feed Prog/Run switch must be in the Run
position for the feed to receive data.

2.7

CWP ServoDial 2000 Interface

The connection to a CWP ServoDial 2000 feed

is as follows:

Table 2.6

CWP ServoDial 2000 Connections

Link PN 106759

OmniLink
Feed Port

Function / Color

CWP

Pin 1
(GND)

Ground (WHITE)

Pin 7

Pin 2
(RXD)

Receive data from
feed (BLACK)

Pin 3

Pin 3
(TXD)

Transmit data to
feed (RED)

Pin 2

Notes:

‚

The feed Panel/Remote switch must be in the
Remote position for the feed to receive data.

‚

The feed Prog/Run switch must be in the Run
position for the feed to receive data.