Omnilink 5000 feed manual – LINK Systems OmniLink - Feed Interface User Manual

Page 39

Advertising
background image

OmniLink 5000 Feed Manual

December 13, 1999

A.6

Manual Rev 2.3

Figure A.9:

OmniLink 5000 Die Protection
Module Circuit Board

‚

Insert the new 5000-7 chip.

‚

Insert the Die Protection board in the card rack.

A.3.6 OmniLink Tonnage Monitor Module

Software Upgrade Procedure

This upgrade procedure applies only if the

OmniLink control has an extended card rack and
has the tonnage monitor module installed.

‚

Review the chip changing rules of section A.1.

‚

Remove power from the OmniLink card rack
and the OIT.

‚

Remove the Tonnage Monitor Module from the
card rack.

‚

Using Figure A.10, locate and remove the 5000-
8 chip.

Figure A.10: OmniLink Tonnage Monitor

Module Circuit Board

‚

Insert the new 5000-8 chip.

‚

Insert the Tonnage Monitor Module in the card
rack.

A.3.7 OmniLink Auto-Setup Module Software

Upgrade Procedure

This upgrade procedure applies only if the

OmniLink control has an extended card rack and
has the auto-setup module installed.

‚

Review the chip changing rules of section A.1.

‚

Remove power from the OmniLink card rack
and the OIT.

‚

Remove the Auto-Setup board from the card
rack.

‚

Remove the module (if present) installed in the
SS1 position.

‚

Using Figure A.11, locate and remove the 5000-
10 chip.

Advertising