OmniLink 5000 Feed Manual

December 13, 1999

2.9

Manual Rev 2.3

2.13

Indramat CLM Interface

Connections to the Indramat CLM are as

follows:

Table 2.12

Indramat CLM Servo Connections

Link PN 106739

OmniLink
Feed Port

Function /
Color

Indramat
CLM
Connector X6

Pin 1
(GND)

Ground
(WHITE)

Pin 7

Pin 2
(RXD)

Receive data
from feed
(BLACK)

Pin 2

Pin 3
(TXD)

Transmit data
to feed (RED)

Pin 3

Notes:

‚

For old communication board only, the
following Parameter Values must be set up at
the CLM:
a) A100 = 3.
b) B102 = 0.
c) B118 = 1 00 0.
d) B119 = 9600 8 1 02.

‚

For new communication board only, the
following Parameter Values must be set up at
the CLM:
a) B102 = 0.
b) B118 first number must not be 0.
c) Feed port baud rate, data bits, and stop bits

must be set at the OmniLink OIT the same
as the CLM.

2.14

Indramat DLC Interface

Connections to the Indramat DLC are as

follows:

Table 2.13

Indramat DLC Servo Connections

Link PN 106744

OmniLink
Feed Port

Function /
Color

Indramat DLC
Connector X31

Pin 1
(GND)

Ground
(WHITE)

Pin 5

Pin 2
(RXD)

Receive data
from feed
(BLACK)

Pin 3

Pin 3
(TXD)

Transmit data
to feed (RED)

Pin 2

No
Connect

Shield
(BARE)

Pin 1

Notes:

‚

For old communication board only, the
following Parameter Values must be set up at
the DLC:
a) A100 = 3.
b) B102 = 0.
c) B118 = 1 00 0.
d) B119 = 9600 8 1 02.

‚

For new communication board only, the
following Parameter Values must be set up at
the DLC:
a) B102 = 0.
b) B118 first number must not be 0.
c) Feed port baud rate, data bits, and stop bits

must be set at the OmniLink OIT the same
as the DLC.