Mixer, Function – Rocktron Xpression User Manual

Page 24

Advertising
background image

Functions and Parameter Descriptions

The next function displayed when turning the FUNCTION SELECT

control is the Mixer function. The Mixer function parameters are included in all
presets—regardless of which effects are active for the current preset - although
the parameter values stored in this function are only for the currently recalled
preset.

This digital mixer allows you to control the signal levels pertaining to each

preset’s configuration and stores those levels for each preset.

The PARAMETER SELECT control will allow you to access each of the following

Mixer parameters.

The PARAMETER ADJUST control will allow you to make adjustments to the

selected parameter:

MIXER

Function

The LEFT DIRECT parameter determines the level of the direct signal
of the current preset at the left output.

The RIGHT DIRECT parameter determines the level of the direct
signal of the current preset at the right output.

The EFFECT LEVEL parameter determines the volume of the overall
effect signal (Chorus, Flange, Pitch Shift, etc.) level.

The DRY PATH parameter determines whether the direct signal is
routed around the effects section (ANALOG) or through the effects
section (DIGITAL). When set to ANALOG, the direct signal is not
passed through any digital processing (i.e., the direct signal remains
analog from input to output). When set to DIGITAL, the direct signal is
passed through the digital HUSH circuitry and effects section.

These DIR/EFF parameters determine the amount of direct signal input
to each individual effect relative to the amount of effect signal. A
setting of "0" is 100% direct signal, while a setting of "100" is 100%
effect signal.

The VOLUME parameter determines the overall signal level of the
current preset.

LEFT DIR

RIGHT DIR

EFFECT LEVEL

DRY PATH
(ANALOG OR
DIGITAL)

PHS DIR/EFF
CHR DIR/EFF
FLN DIR/EFF
REV DIR/EFF

VOLUME

21

Advertising