Troubleshooting

Trouble

Possible Causes

Action

The Blue LED “Heartbeat”

is not functioning.

AC Cord or Power adaptor

is not working correctly or
not plugged in correctly.

Remove all of the plugs and

re-plug them back in.

Sluggish Performance at
Key Telephone –

Press Speakerphone

several time with no
reaction

Lift/Replace Handset

with no reaction


Cable Pairs connect to one
or more KSU digital ports

without a telephone
connected

Remote Connection of

un-terminated cable pair

at KSU port

Install telephones at all

locations wired

Telephone LCD Shows:

“No Link to KSU”

Cable Pairs Connected to

one or more KSU digital
ports without telephone

installed

Remove connection of

un-terminated cable
pairs at the KSU.

Install telephone at all

locations which are
wired.

Telephone reports:
“Register Fail” or cycles

between “Register Fail”
and “Initializing, Please

Wait!”

Cable pairs connected to
one or more KSU digital

ports without a telephone
connected.

Remove connection of

un-terminated cable
pairs at the KSU.

Install telephone at all

locations which are

wired.

One or more extensions
are experiencing static or

distortion.

Not all extensions are
punched down.

Remove connection of

un-terminated cable

pairs at the KSU.

Install telephone at all

locations which are

wired.