3 series connection of modules, 4 examples of series connection, 6wiring – Pilz PDP67 F 4 code User Manual

Page 23: 3 preparing for operation

Advertising
background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-7

6.3

Preparing for operation

6

Wiring

6.3.1.3

Series connection of modules

Series connection of modules

6-

Anschluss_PDP_PSEN_Reihenschaltung_Info

Please note:

The series connection of the modules is always created with the last
free female connector X2 ... . X5 and the X1 female connector of the
next module. The adapter

PDP67 Connector cs/PDP67 Connector

cs VA must be used for connecting the modules in series.

The voltage at the last module must not fall below the permitted sup-
ply voltage level. Please refer to the operating manual for the sensors
used for the permissible values for the supply voltage (see "Voltage
tolerance" in the chapter entitled "Technical details"). An example of
how the voltage drop is calculated can be found in the chapter enti-
tled "Voltage drop".

6.3.1.4

Examples of series connection

Examples of series connection

6-

Anschluss_PDP_PSEN_Reihenschaltung_4_Sensoren

Connection example 1: Series connection for connecting four sensors
(X1 ... X4) to the first module

*Adapter:

PDP67 Connector cs/PDP67 Connector cs VA

Anschluss_PDP_PSEN_Reihenschaltung_3_Sensoren

*

*

FS: Fail-Safe

ST
ST
ST

FS

Adapter

Adapter

Adapter

Evaluation device

PLC

ST: Standard

*

PSEN PSEN

PSEN

PSEN PSEN

PSEN PSEN

PSEN

PSEN

PSEN