6 example of calculation, 7 standard values for a range of cable types, 6wiring – Pilz PDP67 F 4 code User Manual

Page 25: 3 preparing for operation

Advertising
background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

6-9

6.3

Preparing for operation

6

Wiring

6.3.1.6

Example of calculation

Example of calculation

6-

Verdrahtung_PDP_PSEN_Leitungslänge-Spannungsabfall-Beispiel

A 0.25 mm² sensor cable is used.
Voltage drop per 10 m and per 100 mA: 0.15 V

6.3.1.7

Standard values for a range of cable types

Standard values for a range of cable types

6-

Verdrahtung_PNOZ ml2p_Leitungslänge-Spannungsabfall-Richtwerte

Guidelines for calculating the voltage drop on various cable types

Cable type

Voltage drop per 10 m and per 100
mA

PSS SB BUSCABLE LC

0.1 V

Sensor cable 0.25 mm

2

0.15 V

Sensor cable 0.34 mm

2

0.11 V

Sensor cable 0.5 mm

2

0.07 V

PNOZmulti Base Unit

4*I0+I1+I2+I3+I4

865 mA

U = 1,3 V

I0+I4 =

205 mA

U = 0,923 V

2*I0+I3+I4

410 mA

U = 0,3 V

3*I0+I2+I3+I4

615 mA

U = 0,92 V

10 m

5 m

10 m

30 m

I4

»

200 mA

I3

»

200 mA

I2

»

200 mA

I1

»

250 mA

PSEN

PSEN PSEN

PSEN

PSEN PSEN

PSEN

PSEN PSEN

PSEN

PSEN PSEN

PSEN

PDP67 F 4 code

I0=5 mA

PDP67 F 4 code

I0=5 mA

PDP67 F 4 code

I0=5 mA

PDP67 F 4 code

I0=5 mA

Advertising