[1] Depends on the servo amplifier you are using
Cable features:
• Cable cross section: max. 14 mm
- Wires for supply voltage: max. 3 x 2.5 mm
2
- Wire for earth conductor PE: max. 1 x 2.5 mm
2
- Wires for thermal switch: max. 2 x 1 mm
2
- Wires for holding brake: max. 2 x 1 mm
2
• Cable runs:
- Depend on the requirements of the servo amplifier you are using
Fig. 7-8: Connection cable for the terminal box (servo motors AC1 and AC2)
Connection cable (servo motor)
Servo amplifier
Shield
1
3
4
PE
BR
BR2
Phase U
Phase W
Phase V
Holding brake
+ 24 VDC
0 VDC
Thermal switch
Thermal switch
Earth conductor
Phase U
Phase W
Phase V
Holding brake
+ 24 VDC
0 VDC
Thermal switch
Thermal switch
Earth conductor