Nexen TC920V 964356 User Manual

Page 34

Advertising
background image

31

FORM NO. L21268-C-1013

No.

Parameter Name

Factor-Set Value Unit

Adjustment Range

1

Start Level

20

%

0 to 100

2

Start Time

2.0

sec

0.0 to 20.0

3

Start I Time

1.5

sec

0.1 to 10.0

4

Stop Level

2.0

x

1.0 to 5.0

5

Stop Time

5.0

sec

0.0 to 20.0

6

Stop Minimum Value

10

%

0 to 50

7

Stop I Time

1.50

sec

0.1 to 10.0

8

Filter for Recording

1.00

sec

0.02 to 5.00

9

Filter for Display

1.50

sec

0.50 to 5.00

10

Control Filter

0.2

sec

0.02 to 0.5

11

Proportional Gain

50

%

5 to 400

12

Integral Time

1.0

sec

0.1 to 20.0

13

Differential Time *1

0.0

sec

0.0 to 10.0

14

Taper Ratio

0

%

0 to 100

15

Taper Start Point

0

%

0 to 100

16

Taper End Point

100

%

0 to 100

17

Zero Tension

10

%

0 to 100

18

Upper Limit of Tension

110

%

0 to 110

19

Predrive

10

%

0 to 100

20

Break Point Deviation Width

0

%

0 to 50

21

Break Point Correction Gain

100

%

0 to 100

22

Paste Level

100

%

0 to 600

23

Paste Time

5.0

sec

0.0 to 20.0

24

Measure-roll Diameter

100

mm

100 to 500

25

Encoder Pulse

1000

p/r

100 to 2000

26

Minimum Diameter

150

mm

50 to 2000

27

Correction Factor

50

%

10 to 1000

28

Correction Time

0

sec

0 to 10

29

Paste Bias

0

%

0 to 100

30

Proportional Gain 1 (+ deviation)

63

%

5 to 400

31

Integral Time 1 (+ deviation)

0.8

sec

0.1 to 20.0

32

Proportional Gain 1 (– deviation)

40

%

5 to 400

33

Integral Time 1 (– deviation)

1.3

sec

0.1 to 20.0

34

Proportional Gain 2 (+ deviation)

75

%

5 to 400

35

Integral Time 2 (+ deviation)

0.5

sec

0.1 to 20.0

36

Proportional Gain 2 (– deviation)

25

%

5 to 400

37

Integral Time 2 (– deviation)

1.5

sec

0.1 to 20.0

38

Emergency Stop Correction

20

%

0 to 200

39

Maximum Diameter

2000

mm

100 to 2000

40

Start Mode

1

0 to

41

Stop Mode

1

0 to

42

Taper Mode

0

0 to

43

Paste Mode

0

0 to

44

Correction Mode

0

0 to

Memory DIP Switch 0

00000000

0 to

Memory DIP Switch 1

00000000

0 to

Memory DIP Switch 2

00000000

0 to

9. PARAMETER LIST

Advertising