31
FORM NO. L21268-C-1013
No.
Parameter Name
Factor-Set Value Unit
Adjustment Range
1
Start Level
20
%
0 to 100
2
Start Time
2.0
sec
0.0 to 20.0
3
Start I Time
1.5
sec
0.1 to 10.0
4
Stop Level
2.0
x
1.0 to 5.0
5
Stop Time
5.0
sec
0.0 to 20.0
6
Stop Minimum Value
10
%
0 to 50
7
Stop I Time
1.50
sec
0.1 to 10.0
8
Filter for Recording
1.00
sec
0.02 to 5.00
9
Filter for Display
1.50
sec
0.50 to 5.00
10
Control Filter
0.2
sec
0.02 to 0.5
11
Proportional Gain
50
%
5 to 400
12
Integral Time
1.0
sec
0.1 to 20.0
13
Differential Time *1
0.0
sec
0.0 to 10.0
14
Taper Ratio
0
%
0 to 100
15
Taper Start Point
0
%
0 to 100
16
Taper End Point
100
%
0 to 100
17
Zero Tension
10
%
0 to 100
18
Upper Limit of Tension
110
%
0 to 110
19
Predrive
10
%
0 to 100
20
Break Point Deviation Width
0
%
0 to 50
21
Break Point Correction Gain
100
%
0 to 100
22
Paste Level
100
%
0 to 600
23
Paste Time
5.0
sec
0.0 to 20.0
24
Measure-roll Diameter
100
mm
100 to 500
25
Encoder Pulse
1000
p/r
100 to 2000
26
Minimum Diameter
150
mm
50 to 2000
27
Correction Factor
50
%
10 to 1000
28
Correction Time
0
sec
0 to 10
29
Paste Bias
0
%
0 to 100
30
Proportional Gain 1 (+ deviation)
63
%
5 to 400
31
Integral Time 1 (+ deviation)
0.8
sec
0.1 to 20.0
32
Proportional Gain 1 (– deviation)
40
%
5 to 400
33
Integral Time 1 (– deviation)
1.3
sec
0.1 to 20.0
34
Proportional Gain 2 (+ deviation)
75
%
5 to 400
35
Integral Time 2 (+ deviation)
0.5
sec
0.1 to 20.0
36
Proportional Gain 2 (– deviation)
25
%
5 to 400
37
Integral Time 2 (– deviation)
1.5
sec
0.1 to 20.0
38
Emergency Stop Correction
20
%
0 to 200
39
Maximum Diameter
2000
mm
100 to 2000
40
Start Mode
1
0 to
41
Stop Mode
1
0 to
42
Taper Mode
0
0 to
43
Paste Mode
0
0 to
44
Correction Mode
0
0 to
Memory DIP Switch 0
00000000
0 to
Memory DIP Switch 1
00000000
0 to
Memory DIP Switch 2
00000000
0 to
9. PARAMETER LIST