Port Name

Required

Description

signa

No

Specifies the numerical representation of the

dataa[]

port. If

the

signa

port is high, the multiplier treats the

dataa[]

port

as signed two's complement. If the

signa

port is low, the

multiplier treats the

dataa[]

port as an unsigned number.

signb

No

Specifies the numerical representation of the

datab[]

port. If

the

signb

port is high, the multiplier treats the

datab[]

port

as signed two's complement. If the

signb

port is low, the

multiplier treats the

datab[]

port as an unsigned number.

Table 5-6: ALTMULT_ACCUM IP Core Output Ports

Port Name

Required

Description

overflow

No

Overflow port for the accumulator.

result[]

Yes

Accumulator output port. The size of the output port depends

on the

WIDTH_RESULT

parameter value.

scanouta[]

No

Output of the first shift register. The size of the output port

depends on the

WIDTH_A

parameter value. When instantiating

the ALTMULT_ACCUM IP core with the MegaWizard Plug-

In Manager, the MegaWizard Plug-In Manager renames the

scanouta[]

port to

shiftouta

port.

scanoutb[]

No

Output of the second shift register. The size of the input port

depends on the

WIDTH_B

parameter value. When instantiating

the ALTMULT_ACCUM IP core with the MegaWizard Plug-

In Manager, the MegaWizard Plug-In Manager renames the

scanoutb[]

port to

shiftoutb

port.

UG-M10DSP

2014.09.22

ALTMULT_ACCUM Ports

5-9

ALTMULT_ACCUM (Multiply-Accumulate) IP Core References