Chapter 3: Functional Description

3–5

RS Decoder

December 2014

Altera Corporation

Reed-Solomon Compiler

User Guide

The RS decoder observes Avalon-ST interface standard for input and output data. One
clock cycle after the decoder asserts sink_ena, you can assert sink_val. The decoder
accepts the data at rsin as valid data. The codeword is started with sink_sop. The
numcheck

and numn signals are latched to sink_sop.

The codeword is finished when sink_eop is asserted. If sink_ena is de-asserted, from
one clock cycle onwards the decoder cannot process any more data until sink_ena is
asserted again.

At the output the operation is identical. If you assert source_ena, the decoder asserts
source_val

and provides valid data on rsout if available. Also, it indicates the start

and end of the codeword with source_sop and source_eop respectively.

Figure 3–4

shows the operation of the RS decoder.

The decoder has the following optional outputs, which you turn on in IP Toolbench:

Error symbol

Bit error count

Error Symbol Output

The error symbol output, rserr is the Galois field error correction value. The RS
decoder finds the error values and location and adds these values in the Galois field to
the input value. Galois field addition and subtraction is the same operation. An XOR
operation performs this operation between bits of the two values.

Figure 3–4. Decoder Timing

clk

sink_ena

sink_val

sink_sop

sink_eop

rsin[8:1]

source_ena

source_val

source_sop

source_eop

rsout[8:1]

numcheck[4:1]

numn[4:1]

01 02 03 04 05 06 07 08 P1 P2 P3 P4 P5

09 10 11 12 13

01 02 03 04 05 06 07 08 P1 P2 P3 P4 P5

12

05

05

13

13

Advertising