Development board setup, Powering up the board, Chapter 4. development board setup – Altera Transceiver Signal Integrity User Manual

Page 15: Powering up the board –1

Advertising
background image

December 2011

Altera Corporation

Transceiver Signal Integrity Development Kit,

Stratix IV GX Edition User Guide

4. Development Board Setup

The instructions in this chapter explain how to power up the signal integrity
development board.

Powering Up the Board

To power up the board, perform the following steps:

1. Verify that the MAX/JTAG jumper J26 is OFF, and that the mini-DIP switch SW2

settings located adjacent to jumper J62 match the settings in the following table:

1

Maintain these settings as they control the speed of the board oscillator. For
more information, refer to the

Transceiver Signal Integrity Development Kit,

Stratix IV GX Edition Reference Manual

.

2. Connect the power cable to the board and plug the other end into a power outlet.

3. Connect the DC adapter (+16 V, 3.75 A) to the DC power jack (J1).

c

Use only the supplied 16-V power supply. Power regulation circuitry on the
board could be damaged by supplies greater than 16 V.

4. Ensure the POWER switch (SW1) is in the ON position. When power is supplied to

the board, LED D3 turns on indicating that the board has power.

After the board powers up, the on-board flash memory, which ships preprogrammed
with the factory design, automatically configures the Stratix IV GX device. The
FACTORY LED illuminates, signaling that the Stratix IV GX device is configured with
the preprogrammed factory design.

Table 4–1.

Switch Pin

SW2.1

SW2.2

SW2.3

SW2.4

Label

S0

S1

S2

S3

Position

up or 0

down or 1

down or 1

down or 1

Advertising