Resets, Help, Power down – Altera Transceiver Signal Integrity User Manual

Page 22: Serial loopback, Resets –4 help –4 power down –4 serial loopback –4, Gs shown in, Table 6–2

Advertising
background image

6–4

Chapter 6: Stratix IV GX Transceiver Signal Integrity Demonstration

Running the Demonstration Application and Test Designs

Transceiver Signal Integrity Development Kit,

December 2011

Altera Corporation

Stratix IV GX Edition User Guide

c

For operating system stability, keep the USB cable connected and the board
powered ON when running the demonstration application.

The following list defines the analog setting parameters in the control panel window:

Resets

The following list describes the available resets:

1

After the System Reset is asserted, the DataChk Status may show unsynced for some
channels due to the asynchronous nature of the reset. Asserting the Data Patrst
synchronizes the error checker to the transmitted data.

Help

The Help button displays the image of the Stratix IV signal integrity board and also
highlights the channel locations and their data rates based on the .sof loaded.

Power Down

Turn on Powerdown to power down the transceiver block.

Serial Loopback

Serial loopback is available for all the channels and can be controlled during run time.
After the serial loopback status in the interface changes, the DataChk Status field
may show unsynced for some channels due to the asynchronous nature of the serial
loopback signal. The Data Patrst should be asserted in this case to synchronize the
error checker with the transmitted data.

Table 6–2. Jumper Header Connections

(1)

Jumper Header Connection

VCCHTX (Volt)

Jumper Header Connection

VCCA_L/R (Volt)

Pins 1 and 2

1.4 V

Pins 2 and 3

3.0 V

Note to

Table 6–2

:

(1) Before you power up the board, specify the VCCHTX and the VCCA jumper settings.

Table 6–1.

Parameter

Description

VOD

differential output driver voltage.

EQ

equalization.

Gain

DC gain.

PE

preemphasis/deemphasis.

pre, 1stpost, and 2ndpost settings represent different taps.

Table 6–2.

Reset

Description

System

Reset for the transceiver.

Error

Reset for all the error counters to zero.

Advertising