3. INSTALLATION

page 3-4 Operation manual b40, chapter 3 -installation-


The digital audio toolbox b40 can transmit specific device
statuses via parallel Tally lines.

use:

Control of the remote-controlled changeover of
presets

connector:

D-SUB 15pin, male


Pin assignments


Pin

Signal name

I/O

Functions

1

T1 open contact

O

preset1 recalled

2

T2 open contact

O

preset2 recalled

3

T3 open contact

O

preset3 recalled

4

T4 open contact

O

preset4 recalled

5

T5 open contact

O

preset4 recalled

6

T6 open contact

O

preset4 recalled

7

T7 open contact

O

preset4 recalled

8

T8 open contact

O

preset4 recalled

9

T9 open contact

O

mute

10

T10 open contact

O

bypass

11

T11 open contact

O

Not used

12

T12 open contact

O

Not used

13

T13 open contact

O

Not used

14

T14 open contact

O

Not used

15

root

Common root contact

3.7.2