3. INSTALLATION

operation manual d06, chapter 3 - Installation - page 5 of 10


The digital audio level processor d06 can aknowledge specific device statuses
via parallel GPO (Tally) lines.

Use to :

monitor the d06 status



Connector :

D-SUB 25pin

female panel jack



Pin assignment of the connector :

Pin

Signal name

Functions

1

Tally 1 normally closed

2

Tally 1 normally opened

Defined by d06 config

3

TALLY 2 common

4

Tally 3 normally closed

5

Tally 3 normally opened

Defined by d06 config

6

TALLY 4 common

7

Tally 5 normally closed

8

Tally 5 normally opened

Defined by d06 config

9

Tally 6 common

10

Tally 7 normally closed

11

Tally 7 normally opened

Defined by d06 config

12

TALLY 8 common

13

+ 5V

110 Ohm

14

TALLY 1 common

15

Tally 2 normally closed

16

Tally 2 normally opened

Defined by d06 config

17

TALLY 3 common

18

Tally 4 normally closed

19

Tally 4 normally opened

Defined by d06 config

20

TALLY 5 common

21

Tally 6 normally closed

22

Tally 6 normally opened

Defined by d06 config

23

TALLY 7 common

24

Tally 8 normally closed

25

Tally 8 normally opened

Defined by d06 config

Screen

-5V

GND of do6 chassis



Electrical specifications :

Tally output relay :

common / normally closed / normally opened

24V - 1A

125V - 0,5A

P

max

= 62,5VA

3.7.3

GPO (TALLY)