9.2 Operations with K&F System Controller


For optimal performance with an extended functional range we recommend using a
K&F system controller. Instructions for use, connecting diagrams and detailed descrip-
tions of the latest controller models ‘CD 24’ and ‘CD 44’ you can find in the correspond-
ing user’s manuals.

9.3 Maximum Configuration

It is possible to use a large number of SP speakers in parallel simultaneously, however,
this number is limited according to the permitted minimum load impedance of the sig-
nal source (e.g. mixer, equalizer, etc.).
The total input impedance of all SP speakers must be larger than the permitted mini-
mum load impedance of the signal source. If no manufacturer’s recommendations can
be found, take the output impedance of the signal source. In this case we recommend a
total input impedance at least 10 times higher than the stated output impedance of the
signal source.
(The output impedance of your signal source can normally be found under ‘Technical
Specifications’ in the manufacturer’s instruction manual.)

Definition:

source

signal

of

impedance

output

R

OUT

=

50.000Ω

50kΩ

speaker

-

SP

impedance

input

R

IN

=

=

=

speakers

SP

of

number

d

recommende

maximum

n

MAX

=


The maximum number of SP speakers can be calculated with this formula:

10

50

10

n

MAX.

×

=

×

<

OUT

OUT

IN

R

k

R

R


Example:

= 75

OUT

R

10

75

000

.

50

10

n

MAX.

x

R

R

OUT

IN

=

×

<

66

n

MAX.

<

Important