Wiring and Control



All electrical work must be carried out by a properly licensed electrician, in compliance

with local electrical standards. Failure to observe this point will void the factory

warranty for the Tempest Enclosure.

1

Switch off power to the branch circuit, carefully following lockout and tag-out procedures.

Failure to do so could cause serious injury or death.

2

You will need two electrical junction boxes, located within a short distance from the

enclosure, one for power, one for DMX control. Use outdoor-rated flexible conduit between

the box and the enclosure.

3

AC and control circuits must be wired in separate conduits.

Conduit entry holes

Power and DMX conduit entries

The conduit entry holes accept US ½” conduit fittings, and

international 20-22mm (OD) conduit fittings.

AC

Power

DMX
Control

Flexible Conduit

120VAC,
or

208VAC
or
230VAC

Lighting
Control

AC Power

DMX Control

Ø 0.875”
22.2mm