Tornado Enclosure User Manual

page 23

Control Interface


LED Indicators

Heater

SHORT PULSES

(green)

Lamp is off

Temperature is normal

Heater is pulsing to prevent condensation

ON (Green)

Temperature is LOW

Heater is ON

OFF

Lamp is on

Temperature is normal

Fan

PULSES

(green)

Lamp is off

Temperature is normal

Fan is moving small amount of air to prevent

condensation

ON (Green)

Lamp is ON, or

Temperature is HIGH

Fan is cooling enclosure

Lamp On

ON (Green)

Current sensing shows lamp is ON

Lamp hour counter is running

OFF

Current sensing shows lamp is OFF

Lamp hour counter is not running

Lamp Relay

ON (Green)

Lamp relay is closed (normal)

Luminaire power receptacle is energized

OFF

Lamp relay open (due to overtemp or DMX

control). Luminaire is electrically isolated

Temp

ON (Green)

Temperature is in normal range

ON (Red)

Temperature is above Top setting, or below

bottom setting

FLASHING (Red)

Temperature is above Cutoff level

Luminaire power is isolated

DMX

OFF

DEC3.2 is in BASIC Mode – DMX not used

ON (GREEN)

Good DMX or RDM data packet received.

ON (RED)

Control Mode: DMX Fail

Monitor Mode: No RDM information being

received (this is normal)