DEC3.2 Control Parameters

Temperature Settings:

Cutoff Temp

Range 0-15°C, Default = 15°C

Top Set

Range 35-45°C, Default = 40°C

Bottom Set

Range 0-10°C, Default = 10°C

Notes:
1 The Cutoff Temperature is an incremental temperature range above the Top

Set temperature. So the default 15°C cutoff and 40°C Top Set means that the

lamp relay will open when a temperature of 55°C is reached.

2 In moving light enclosures the temperature sensor is located in the exhaust

airflow. Temperatures shown may be higher than those around the luminaire.

3 We recommend using the factory default settings for several weeks or

months before making any changes. In most cases they will not be necessary.

Humidity

Range 50-90%, Default 80%

The threshold at which incoming air is more aggressively heated to remove

moisture.

DMX Address Range 001-510, Default 001

Sets the DMX address for the lamp relay control.

Fan Overrun

Range 1-15 minutes, Default 5 minutes

Time that the enclosure fan(s) will run after the fixture/projector lamp is turned

off.

Temp C/F

Display Degrees Celsius or Fahrenheit. Default Celsius

Note that temperature settings must always be Celsius.

Lamp Hours

Default 0000

Counts lamp hours – you must reset to zero when changing lamps.

Over-temperature Warning, Fans on

Normal operation

Under-temperature Warning, Heater on, Fans off

Lamp relay open – Lamp OFF