Operating Modes

DEC3.2 may operate in one of four modes, set using either the Front Panel or by RDM control. In

all configurations, the luminaire inside the enclosure may also be an RDM enabled device.

Basic Mode (factory setting)

Standard temperature settings

DMX and RDM disabled

Best for standalone operation

Monitor Mode

As Basic mode, plus:

RDM status reporting

RDM configuration – settings may be changed remotely or at the enclosure control

panel

DEC3.2 does not require a DMX signal to operate

Control Mode

As Basic mode, plus:

Enclosure functions as a 1-channel DMX device, with remote control of the lamp relay

o

DMX level > 75% enables normal relay operation (normally ON)

o

DMX level < 25% disables normal relay operation (relay turns OFF)

o

This allows you to force a hard reset of the lamp relay in the event of a

luminaire malfunction

Control mode is recommended for show control applications, but can be risky in live

show operation.

Service Mode

For trained service personnel only

Normal operation is suspended and the enclosure functions as a 3-channel DMX

device:

o

Lamp Relay

o

Fans

o

Heater

Service mode is ONLY for troubleshooting – DO NOT use Service mode for normal

operation.