Tempest TornadoRetrofit Kits User Manual

Page 25

Advertising
background image



Tornado Enclosure User Manual

page 25

SET DMX CURVE

DMX Curves affect the way the fixture relay is controlled in Control Mode.

DMX levels are shown as %.

Response Curve 1 (default)

DMX level 0-25

Relay disabled (open)

DMX level 26-75

No change to relay status

DMX level 76-100

Relay enabled (normally closed)

Response Curve 2

DMX level 0-19

No change to relay status

DMX level 20-40

Relay disabled (open)

DMX level 41-59

No change to relay status

DMX level 60-80

Relay enabled (normally closed)

DMX level 81-100

No change to relay status

SET DMX RESPONSE

DMX Response sets a delay time before DMX Control Mode settings are acted on.

Setting a response delay of a few seconds would prevent unintended fixture relay

state changes in the event of a short accidental change in DMX level.

NOTE: from firmware revision 0.00.100, DEC holds last valid DMX level if DMX is

interrupted.

Response Delay Values are:

No Delay (default), 1, 2, 5, 10, 15, 20, 30, 60 seconds.

SET TEMP UNITS

Choose to display temperature values in Celsius or Fahrenheit (default Celsius)

Note that temperature settings must be entered in Celsius.

SET TEMP RANGES

Set three temperature trigger points for Bottom, Top and Cutoff temperatures, in °C.
TEMP BOTTOM

(default 10°C, permissible range 0-10°C).
TEMP TOP

(default 40°C, permissible range 35-45°C).
TEMP CUTOFF

(default 15°C, permissible range 0-15°C).

SET FAN OVERRUN

Fan will keep running after luminaire lamp is sensed to change from ON to OFF, to allow

the lamp to cool safely.

Default is 5 minutes, permissible range 0-15 minutes.

SET LAMP ON POINT

Set the threshold at which the enclosure determines that the lamp is on. Range between

0.1 amp – 2.0 amps, in 0.1 amp steps. Default is 1.0amp.