16

SIG_HEIGHT

st

st

displayable input line
count

Rd

0

65535 0

Unit : pixels

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8

0 = Analog Plug
1 = DVI Plug
2 = SDI Plug

SIG_HDCP

sn

sn

HDCP input status

Rd

0

1

0

1 = HDCP content

0 = Input1
1 = Input2
2 = Input3
3 = Input4

0 = Analog Plug
1 = DVI Plug
2 = SDI Plug

Input
Settings

SET_DEFAULT

SK SK

current input default
settings (auto clear)

Rd/Wr 0

7

0

0 = None
1 = positioning & Cropping
2 = Colorimetry
4 = Hard
7 = all

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8

0 = Analog Plug
1 = DVI Plug
2 = SDI Plug

SET_HPOS

SH SH

input signal horizontal
position

Rd/Wr 0

2048

1024

1024 = neutral

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8

0 = Analog Plug
1 = DVI Plug
2 = SDI Plug

SET_VPOS

SV SV

input signal vertical
position

Rd/Wr 0

2048

1024

1024 = neutral

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8

0 = Analog Plug
1 = DVI Plug
2 = SDI Plug