Analog Way DI-VENTIX II - Ref. DVX8044 Programmer's Guide User Manual
Page 16
16
SIG_HEIGHT
st
st
displayable input line
count
Rd
0
65535 0
Unit : pixels
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
0 = Analog Plug
1 = DVI Plug
2 = SDI Plug
SIG_HDCP
sn
sn
HDCP input status
Rd
0
1
0
1 = HDCP content
0 = Input1
1 = Input2
2 = Input3
3 = Input4
0 = Analog Plug
1 = DVI Plug
2 = SDI Plug
Input
Settings
SET_DEFAULT
SK SK
current input default
settings (auto clear)
Rd/Wr 0
7
0
0 = None
1 = positioning & Cropping
2 = Colorimetry
4 = Hard
7 = all
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
0 = Analog Plug
1 = DVI Plug
2 = SDI Plug
SET_HPOS
SH SH
input signal horizontal
position
Rd/Wr 0
2048
1024
1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
0 = Analog Plug
1 = DVI Plug
2 = SDI Plug
SET_VPOS
SV SV
input signal vertical
position
Rd/Wr 0
2048
1024
1024 = neutral
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
6 = Input7
7 = Input8
0 = Analog Plug
1 = DVI Plug
2 = SDI Plug