Analog Way DI-VENTIX II - Ref. DVX8044 Programmer's Guide User Manual
Page 32
32
P_KEYING_GRAB_ENABLE
Kg Kg
keying grabber mode
Rd/Wr 0
1
0
1 = grabber enable
0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized
Preset 1
4 = Memorized
Preset 2
5 = Memorized
Preset 3
6 = Memorized
Preset 4
P_KEYING_GRAB_H
Kh Kh
keying grabber H
position
Rd/Wr 0
65535 32768
in % of output horizontal size
0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized
Preset 1
4 = Memorized
Preset 2
5 = Memorized
Preset 3
6 = Memorized
Preset 4
P_KEYING_GRAB_V
Kv
Kv
keying grabber V
position
Rd/Wr 0
65535 32768
in % of output vertical size
0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized
Preset 1
4 = Memorized
Preset 2
5 = Memorized
Preset 3
6 = Memorized
Preset 4
P_KEYING_GRAB_GET
Kc
Kc
keying grabber enable
Rd/Wr 0
1
0
(auto clear)
0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized
Preset 1
4 = Memorized
Preset 2
5 = Memorized
Preset 3
6 = Memorized
Preset 4