Analog Way DI-VENTIX II - Ref. DVX8044 Programmer's Guide User Manual

Page 33

Advertising
background image

33

P_CLONE

PC PC

clone mode (copy Next
preset parameters to
Current)

Rd/Wr 0

2

0

0 = never equalize Main and
Preview for this vars group
1 = equalize only for front
panel settings
2 = always equalize Main and
Preview for this vars group

0 = Keying group
1 = DualHead group
2 = Position group
3 = Size group
4 = Crop group
5 = Transparency
group
6 = Freeze group
7 = Border group

P_UPDATE

IU

IU

preset updated

Rd/Wr 0

1

1

0 = before sending the preset
1 = after sending the preset

P_LINKED_INPUT

IL

IL

dualhead inputs (use
lower number of the pair)
(ex: 1=input1 or input2)

Rd/Wr 0

4

0

0 = No Input
1 = Input1 / Frame1 / Logo1 /
MaskFrame1
2 = Input2 / Frame2 / Logo2
3 = Input3 / Frame3 / Logo3
4 = Input4 / Frame4 / Logo4

0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized
Preset 1
4 = Memorized
Preset 2
5 = Memorized
Preset 3
6 = Memorized
Preset 4

P_FORCE_DURATION

FD FD

preset force duration
(overwrite layers
durations)

Rd/Wr 0

255

0

0 = no forcing, else in 1/10
second

0 = Current Preset
1 = Next Preset
2 = Previous Preset
3 = Memorized
Preset 1
4 = Memorized
Preset 2
5 = Memorized
Preset 3
6 = Memorized
Preset 4

Preset
Controls

TAKE

TK TK

TAKE, Next preset
become Current

Rd/Wr 0

1

0

(auto clear)

TAKE_TYPE

TT

TT

next TAKE type

Rd

0

4

0

0 = standard TAKE
1 = sequenced TAKE, due to
not enough front end
2 = sequenced TAKE, due to
not enough scaler
3 = sequenced TAKE, due to
cross not possible
4 = sequenced TAKE, due to
keying cross not possible

TAKE_W_RDY

TR TR

TAKE when ready

Rd/Wr 0

1

0

(auto clear)

TAKEAVA

TA TA

TAKE available

Rd

0

1

0

0 = busy, TAKE not possible

Advertising