Argox OS Series User Manual

Page 40

Advertising
background image

78

Connection with host

Host 25S

Printer 9P

Host 9S

Printer 9P

(PC or compatible)

(PC or compatible)

DTR 20 …… 1 DSR

DTR 4

…… 1 DSR

DSR 6 …… 6 DTR

DSR 6

…… 6 DTR

TX 2

…… 2 RX

TX 3

…… 2 RX

RX 3

…… 3 TX

RX 2

…… 3 TX

CTS 5

…… 7 RTS

CTS 8

…… 7 RTS

RTS 4

…… 8 CTR

RTS 7

…… 8 CTS

GND 7 …… 5 GND

GND 5

…… 5 GND


Alternatively you can just connect the 3 wires in the following way.

Host 25S

Printer 9P

Host 9S

Printer 9P

(PC or compatible)

(PC or compatible)

TX 2

…… 2 RX

TX 3

…… 2 RX

RX 3

…… 3 TX

RX 2

…… 3 TX

GND 7 …… 5 GND

GND 5

…… 5 GND

pin 4

pin 4

pin 5

pin 6

pin 6

pin 7

pin 20

pin 8

The simplest way to connect to other hosts (not PC compatible) or

terminals is:

79

Printer

Terminal/Host

Pin 2- RxData ……… TxData
Pin 3- TxData ……… RxData
Pin 5- Ground ……… Ground

In general, as long as the data quantity is not too large and you

use Xon/Xoff as flow control, it will be problem free.


Baud rate:

2400, 4800, 9600(default), 19200, 38400,

57600, 115200 bauds

.(programmable by

command)


Data format: always 8 data bits, 1 start bit and 1 stop bit.

Parity: always non parity

Handshaking: XON/XOFF as well as CTS/RTS (hardware flow

control).


If you run an application with the bundled printer driver under

Windows and use the serial port, you should check the above

parameters and set the flow control to "Xon/Xoff "or "hardware".

Advertising