Installation of viewcheck – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) User Manual

Page 24

Advertising
background image

Installation of ViewCheck

ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49E)

24

Username: Admin

Password:

Access granted

>enable

#configure terminal

BSF(config)#

BSF(config)#virExecEnv vee0

BSF(VEE-vee0)#diagnostic

BSF(diag-vee0)#

By default, the administrator user name and password are "Admin".

After logging into the ViewCheck CLI, you can list all supported commands by typing '?' on
the CLI console. Following is an example.

BSF(diag-vee0)#?

configure-error-strings User configurable error strings, notified

by ViewCheck when reported by the device.

configure-log-path

Configures the log path where the resluts

are stored.

device-category Configure deviceCategory

diag-service Diag operation(start/stop/restart).

exit Exit from diagnostic

hw-inventory-list

Provides the Inventory of Hardware (Type,

Vendor ID, Major Number, Minor Number and

any associated Details) as detected by the

Diagnostics Application.

list-all-tests Displays all the supported tests on the

Board.

purge-all-log

All log files are Zipped and stored away.

purge-log Purge specific log file.

reload User can issue this command when there

are updates to the User XML.

set-log-level Sets the Log Level of Diagnostic

Application.

Advertising