9 set-poll-interval, Table 4-23, Set-threshold-default – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) User Manual
Page 70: Commands execution
Commands Execution
ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49E)
70
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>deviceCategory</Class>
<Name>vee0-{Dev Cat}</Name>
</Object>
<Method>setThresholdDefault</Method>
<Argument>
<Name>deviceInstance</Name>
<Value>Dev Instance</Value>
</Argument>
<Argument>
<Name>monitorId</Name>
<Value>Monitor ID</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
The following table provides the set-threshold-default command arguments.
Table 4-23 set-threshold-default
Argument
Data Type
Description
Monitor ID
Integer
Type the unique ID of the monitor for which you want to
reset its threshold value to default value.
Dev Instance
Enum
Use list-device-instances command to get the
equivalent enumerated value of supported device
instance
4.4.9
set-poll-interval
set-poll-interval
command is used to set the Poll interval value for monitors.
Syntax for CLI
set-poll-interval monitorId <Monitor ID> deviceInstance <Dev
Instance> pollInterval <PollIntervaLvalue>