9 set-poll-interval, Table 4-23, Set-threshold-default – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) User Manual

Page 70: Commands execution

Advertising
background image

Commands Execution

ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49E)

70

Syntax for XML
<Script>

<InvokeMethod>

<Object>

<Class>deviceCategory</Class>

<Name>vee0-{Dev Cat}</Name>

</Object>

<Method>setThresholdDefault</Method>

<Argument>

<Name>deviceInstance</Name>

<Value>Dev Instance</Value>

</Argument>

<Argument>

<Name>monitorId</Name>

<Value>Monitor ID</Value>

</Argument>

</InvokeMethod>

</Script>]]>]]>

The following table provides the set-threshold-default command arguments.

Table 4-23 set-threshold-default

Argument

Data Type

Description

Monitor ID

Integer

Type the unique ID of the monitor for which you want to
reset its threshold value to default value.

Dev Instance

Enum

Use list-device-instances command to get the
equivalent enumerated value of supported device
instance

4.4.9

set-poll-interval

set-poll-interval

command is used to set the Poll interval value for monitors.

Syntax for CLI
set-poll-interval monitorId <Monitor ID> deviceInstance <Dev

Instance> pollInterval <PollIntervaLvalue>