Installation of viewcheck – Artesyn ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) User Manual
Page 26
Installation of ViewCheck
ViewCheck on ATCA-7470/7475 Installation and Use (6806800S49E)
26
list-tests User can use this command to get
information on the available
Diagnostic tests with details like
tests and sub tests associated,
along with Test
IDs.
set-lower-threshold-info Set the Lower Threshold value for
the Monitor
set-rate set the rate of change value for
network monitors
set-poll-interval-default Set Poll Interval to default value
set-poll-interval Set the Poll Interval
set-threshold-default Set Threshold to default value
set-upper-threshold-info Set the Upper Threshold value for
the Monitor
show-lower-threshold-info Show Lower Threshold info.
show-monitor-id List all monitors for the
deviceCategory.
show-networkcounter-log show network counters log
show-networkerror-log show network errors log
show-poll-interval Show Poll Interval
show-rate show the rate of change value for
network monitors
show-test-help Brief help on the usage of the
Specific Test referred by Test ID.
show-test-result Show test result
show-test-status Show test status
show-upper-threshold-info Show upper threshold info.
start-monitor Start a monitor
start-test Start a test
stop-monitor Stop a monitor
stop-test Stop a test
After logging into the CLI, you can start, stop, and query a test from the CLI. You can view the
details of the test by executing show-test-help command.
To start a test, you can run start-test command with testId, deviceInstance, and
arguments as input to the command. The arguments can be neglected for tests that does not
take any argument as input.